DELTAVENT SF
SINGLE-SKIN FLUE SYSTEMS
Construction
Single-Skin Deltavent sections/fittings are fabricated in a variety of diameters and lengths with a continuously welded vertical seam. The (coupler) characteristics consist of male and female connection sockets complete with a 10mm 90° right angled flange formed at either end of all components.
Single-Skin Deltavent joints shall be secured by clamping an externally fitted V-Band over the mating flanges of the adjoining components. Sealant, available from A1 Flue Systems, should be applied to the inside profile of the V-Band and to both flange faces before installation.

Diameter RANGE
INT DN Std . 100, 125, 150, 200, 250, 300,350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 950, 1000,
(On Demand ) 175, 225, 275, 325, 375, 425, 475, 525, 575, 625, 675, 725, 775, 825, 875, 925, 975,
Quality Assurance
The complete range of components are manufactured, tested and where required installed within scope of stringent quality controlled conditions in accordance with EN ISO 9001:2015 and BS EN 1856-1/2:2009. When requested, A1 Flue Systems shall submit copies of type test reports relating to product performance in addition to the “Certificate of Registration” administered by the British Standards Institute.
Fire Rating
The Single-Skin Deltavent system has been successfully assessed by the Loss Prevention Council for Fire Resistance. A fire rating of 4 hours can be achieved in accordance with stability and integrity criteria of BS 476: part 20. If required, A1 Flue Systems shall submit all test reports in support.
APPLICATION EXAMPLES INCLUDE:
- Condensing boilers
- Smoke extraction systems
- CHP systems
- Fan-assisted flue systems
- Kitchen extraction systems
- Relining of existing chimneys
- Free standing applications up to 3.5m
Performance Designations:
- BS EN1856-2 T600-H1-D-Vm-L20070-G (300)
- BS ENI856-2 T600-H1-D-V2-50070- (300)
- BS EN 1856-2 T600-H1-D-Vim-L20090-G 300)
- BS EN1856-2 T600-H1-D-V2-L50090-G (300)
- BS EN 1856-1 T200-H1-W-Vm-L20070-0 (50)
- BS EN1856-1 T200-H1-W-V2-L50070-0 (50)
- BS EN1856-1 T200-H1-W-Vm-L20090-0 (50)
- BS EN1856-1 T200-H1-W-V2-L50090-0 (50)


Application
The Deltavent system has been successfully assessed by the Loss Prevention Council for Fire Resistance A fire rating of 4 hours can be achieved in accordance with stability and integrity criteria of BS 476: part 20.

Combined Heat & Power
Combined heat and power (CHP), also known as cogeneration, is a highly efficient power plant that generates heat and power simultaneously.

Commercial Ventilation
A1 Flue Systems is a UK specialist in commercial ventilation systems for buildings of all sizes, from small office blocks to schools, hospitals and large skyscrapers.

Condensing Boilers
Condensing boilers capture the exhaust condensation of the burning gas that would otherwise be wasted through the flue.

Fan Dilution Systems
Fan dilution systems were originally developed in order to discharge the flue products from gas-fired appliances at a CO2 level of 1% or less.

Chimneys Liners
Most commercial chimneys were constructed without a liner system, although some were originally built better than others given time they all tend to breakdown over the years.

Moy Park
Commercial

Eclipse Blinds, Glasgow
Commercial

Twickenham Stadium
Sports/Entertainment

Cerium Building, Glasgow
Commercial

Carisbrooke College
Education

Epsom Downs Racecourse
Sports/Entertainment
Literature

Deltavent SF - 0086-CPR 742990 - 1
View

Deltavent SF - 0086-CPR 742991 - 1
View

Deltavent SF - BSRIA Report
View

Deltavent SF - Single Skin Deltavent Specification Sheet (UK)
View

Deltavent SF - SingleSkinDeltavent Product Catalogue
View