DELTAVENT
TWIN-WALL FLUE SYSTEMS
Construction
Deltavent sectional lengths/fitting components are fabricated in a variety of diameters and lengths with continuously welded vertical seams. The Deltavent system also utilises four insulated/non-insulated annular variation options to provide a required minimum external case surface temperature. Inner liner coupler characteristics consist of male and female connection sockets complete with a 10mm 90° right angled flange formed at either end of all components. Deltavent joints shall be secured by clamping an externally fitted V-Band over the mating flanges of the adjoining components.
Diameter RANGE
This double-lined system is available as Deltavent 25 (with a 25mm insulating gap) or Deltavent 50 (with 50mm mineral wool insulation). There are also 75mm and 100mm annuli available on request.
INT DN Std . 100, 125, 150, 200, 250, 300,350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 950, 1000,
(On Demand ) 175, 225, 275, 325, 375, 425, 475, 525, 575, 625, 675, 725, 775, 825, 875, 925, 975.
Quality Assurance
The complete range of components are manufactured, tested, and where required, installed within scope of stringent quality
controlled conditions in accordance with EN ISO 9001:2015 and BS EN 1856-1/2:2009. When requested, A1 Flue Systems shall submit copies of type test reports relating to product performance in addition to the “Certificate of Registration” administered by the British Standards Institute.
Fire Rating
The Deltavent system has been successfully assessed by the Loss Prevention Council for Fire Resistance. A fire rating of 4 hours can be achieved in accordance with stability and integrity criteria of BS 476: part 20. If required, A1 Flue Systems shall submit all test reports in support.
APPLICATION EXAMPLES INCLUDE:
- Diesel generator exhausts
- Condensing boilers
- CHP systems
- Fan-assisted flue systems
- Kitchen extraction systems
- Smoke extraction systems
- Re- lining of existing chimneys
- Free standing applications up to 3.5m
Performance Designations
- BS EN1856-1 T600-H1-D-Vm-L20070-G (50)
- BS EN1856-1 T600-H1-D-V2-L50070-G (50)
- BS EN1856-2 T600-H1-D-Vm-L20090-G (50)
- BS EN1856-2 T600-H1-D-V2-L50090-G (50)
- BS EN1856-1 T200-H1-W-Vm-L20070-0 (50)
- BS EN1856-1 7200-H1-W-V2-_50070-0 (50)
- BS EN1856-1 T200-H1-W-Vm-L20090-0 (50)
- BS EN1856-1 T200-H1-W-V2-L50090-0 (50)
Application
The Deltavent system has been successfully assessed by the Loss Prevention Council for Fire Resistance. A fire rating of 4 hours can be achieved in accordance with stability and integrity criteria of BS 476: part 20. If required, A1 Flue Systems shall submit all test reports in support.
Ovens & Bakery
Commercial bakery ovens are available in various types, each suited to specific production needs.
Biomass Heating System
Biomass heating systems generate heat from biomass. The systems may use direct combustion, gasification, combined heat and power (CHP), anaerobic digestion or aerobic digestion to produce heat.
Combined Heat & Power
Combined heat and power (CHP), also known as cogeneration, is a highly efficient power plant that generates heat and power simultaneously.
Commercial Ventilation
A1 Flue Systems is a UK specialist in commercial ventilation systems for buildings of all sizes, from small office blocks to schools, hospitals and large skyscrapers.
Condensing Boilers
Condensing boilers capture the exhaust condensation of the burning gas that would otherwise be wasted through the flue.
District Heating Systems
It used geothermal energy to provide heat for about 30 houses and started operation in the 14th century.
Fan Dilution Systems
Fan dilution systems were originally developed in order to discharge the flue products from gas-fired appliances at a CO2 level of 1% or less.
Standby Generators
Automatic standby generator systems may be required by building codes for critical safety systems such as elevators in high-rise buildings, fire protection systems and standby lighting.
Diesel Generators
Some applications require the diesel generator to accept a high impact load, with minimal voltage and frequency deviations in the event of a power loss.
Chimney Liners
Most commercial chimneys were constructed without a liner system, although some were originally built better than others given time they all tend to breakdown over the years.
Battersea Power Station
Landmark/Developments
Birmingham New Street Station
Landmark/Developments
Dublin Children's Hospital
NHS
Leadenhall Building
Landmark/Developments
London City Island
Landmark/Developments
The Shard
Landmark/Developments
Literature
Deltavent Twin - 0086-CPR 742990 - 1
View
Deltavent Twin - 0086-CPR 742991 - 1
View
Deltavent Twin - BSRIA Report
View
Deltavent Twin - Deltavent Specification Sheet
View
Deltavent Twin - Twinwall Deltavent Product Catalogue
View
Need a Flue?
We'll Help You!